Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
With air chuck and 15 ft of air hose
NSN
National Stock Number:
TXT
Description:
Reciprocating Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
5.800 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
100.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The method by which a no load condition is obtained for starting the item.AAXV
Unloader Type:
Automatic
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
Reciprocating Compressor Design:
Single acting
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the angular arrangement of the cylinders.AAYA
Cylinder Arrangement Style:
Vertical design
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The volume of the air storage container/s/,including oil storage for rotary designs when applicable.AAYR
Receiver Tank Capacity:
1.60 cubic feet
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0