Part Number X-OMAT2000A

Radiographic Processing Machine

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
x-omat2000a
Demil:
No
Shelf Life:
UOM:
NIIN:
014807478

Part Information
Processing machine radiographic film auto ac

NSN
National Stock Number:
6525-01-480-7478 6525014807478
TXT
Description:
Radiographic Processing Machine
INC
INC
Item Name Code:
24357
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
30.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
20.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
26.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 kilohertz
MRC:
The direction in which the item moves for operation.AHRL
Operational Direction:
Left-hand or right-hand
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Chain
MRC:
Indicates the type of film accommodation provided.ATAB
Film Accommodation Type:
Sheet
MRC:
Designates the size of the film the item is designed to accommodate.BHZY
Film Size Accommodated:
10cm by 10cm through 34cm by 43cm
MRC:
The number of replenisher solution tanks furnished with the item.BKGF
Replenisher Solution Tank Quantity:
0
MRC:
An indication of whether or not an integral replenisher solution pump is included.BKGG
Integral Replenisher Solution Pump:
Included
MRC:
An indication of the speed at which an item may be processed.BKGH
Processing Speed:
Rapid cycle 90 seconds, standard cycle 120 seconds
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
X-omat a table top processor, designed for medium and low volume processing applications; processes 126 sheets of 34cm by 43cm film an hour, processes 209 sheets of 18cm by 24cm sheets an hour

Similar Radiographic Processing Machines

« Imaging Equipment and Supplies: Medical, Dental, Veterinary Catalog
Compare Now »
Clear | Hide