Part Number XMA357-C3282OXYGENCLEAN

Analyzer Assembly

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
xma357-c3282oxygenclean
Demil:
No
Shelf Life:
UOM:
NIIN:
016139982

Part Information
Oxygen analyzer assembly - ngen-30s

NSN
National Stock Number:
6680-01-613-9982 6680016139982
TXT
Description:
Analyzer Assembly
INC
INC
Item Name Code:
77777
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
14.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
33.375 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
24.0 dc
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
This monitor uses a high temperature diffusion type zirconia sensor thatcan be calibrated in air, has a range of 0 to 25 percent, and has an accuracyof plus or minus 0.1 percent over range. It is a low current 24 vdc powered device that uses an integral critical orifice with ms straight thread o-ring connections. It supplies an isolated 4-20 milliamp signal to the plc, which inin turn, shall display the oxygen content of the flowing product gas at all times. The plc automatically adjusts various operating parameters to insure the product gas purity, as indicated by the monitor's input, does not exceed 0.5 percent oxygen.
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Cleaning, packaging, and marking iaw mil-std-1330d.

Similar Analyzer Assemblies

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide