Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Power Operated Drum Winch
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Spray tight
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The means used to operate the item.APHE
Operation Method:
Power
MRC:
The distance between flanges on the drum,and the location on the item.ATWD
Drum Flange To Flange Distance And Location:
12.375 inches first drum
MRC:
The length of a straight line which passes through the center of the drum,and terminates at the circumference,and its location on the item.ATWE
Drum Diameter And Location:
24.000 inches first drum
MRC:
The length of a straight line which passes through the center of the drum flange,and terminates at the circumference,and its location on the item.ATWF
Drum Flange Diameter And Location:
33.562 inches first drum
MRC:
The total load the item is capable of moving at selected speeds and the drum location.ATWN
Load Limit At Selected Speed And Drum Location:
7500.0 pounds single speed first drum and 7500.0 pounds second speed first drum
MRC:
The distance that the item will move per minute,per specific measurement scale.ATWP
Travel Rate Per Minute:
20.0 feet and 80.0 feet
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
25.00 horsepower
MRC:
The design on the drum surface.ATYH
Drum Surface Design:
Grooved
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Any acceptable
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0