Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Scale calibration: 10 deg, 100 deg; scale name: turbine inlet temp, turbine inlet temp; electrical connection controlling agency: ana; panel mounted body size: 1.938 in.Nom; encasement feature: included
NSN
National Stock Number:
TXT
Description:
Electrical Temperature Indicator
MRC:
An indication of the marking/s/ on the scale and the surface finish.ABFN
Scale Marking And Surface Finish:
Letters fluorescent and lined increments fluorescent and numerals fluorescent
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
1.938 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
5.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
10
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
An indication of the scale range.APSK
Scale Range:
+0.1/+1200.0 degrees celsius 2nd indicator 2nd scale
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+100.0 degrees celsius 1st indicator 1st scale
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
And10066d-18-1p
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Clock-hand all pointers
MRC:
The means by which the illuminated color is generated.AWHH
Illumination Color Generation Method:
Fluorescence
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 panel
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the outside circumference.CXQH
Dial Outside Diameter:
2.000 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single