Part Number 7022SD

Relay-switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
7022sd
Demil:
No
Shelf Life:
UOM:
NIIN:
006313066

Part Information
Off-delay operation, calibrated timing head

NSN
National Stock Number:
5999-00-631-3066 5999006313066
TXT
Description:
Relay-switch
INC
INC
Item Name Code:
00448
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
2.830 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.520 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.570 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Relay
MRC:
The quantity and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the item.AFTL
Contact Form Arrangement:
2c
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four tapped holes on back plate
MRC:
Indicates the type of action provided.AMWM
Action Type:
Time delay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Time delay
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Dc
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
250.0
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Dc
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 200.0 and 300.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
1dpdt
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,that make up the switching structure of the switch.APLR
Err Default:
Err default
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,that make up the switching structure of the switch.APLR
Switch Contact Form Arrangement:
2c
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
250.0
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Err Default:
Err default
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Continuous Load Dc Voltage Rating:
250.0 volts
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Err Default:
Err default
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Continuous Load Percentage Per Specificationified Tripping Action Time:
90.0
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
1dpdt

Similar Relay-switches

« Miscellaneous Electrical and Electronic Components Catalog
Compare Now »
Clear | Hide