Contact ratings: 125vac, 60vdc maximum operating voltage; 1a maximum current; single crossbar mechanism; 800 ohm coil resistance

NSN
National Stock Number:
5945-01-612-0956 5945016120956
TXT
Description:
Hybrid Relay
INC
INC
Item Name Code:
31445
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 10.4 millimeters and 10.8 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 3.9 millimeters and 4.3 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 6.8 millimeters and 7.2 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0 to 70.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C-10256c/brr-6 trident, cont ind
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
12.0 volts coil
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, single throw, normally open
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
15.0 milliamperes coil
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.4 milliseconds release
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
1.1 milliseconds operate
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 pin